Project

General

Profile

Actions

Bug #2534

closed

Network connections freeze with heavy email traffic

Added by ftigeot about 11 years ago. Updated about 11 years ago.

Status:
Resolved
Priority:
Normal
Assignee:
-
Category:
-
Target version:
-
Start date:
03/27/2013
Due date:
% Done:

100%

Estimated time:

Description

When under heavy load (receiving a stream of mails at 1Gb/s from a LAN machine), network connections freeze on a mail relay machine.
This machine is also a PPP/ADSL router.

The console shows this message:
Warning, objcache(cluster mbuf): Exhausted!

netstat -m output:
5306/4480 mbuf clusters in use (current/max)

Some processes (most often ppp and sendmail) end up in a weird state, as shown by these top outputs:

PID USERNAME   NICE  SIZE    RES    STATE CPU  TIME   CTIME    CPU COMMAND
1879 root 0 14M 2864K CPU0 0 0:00 0:00 0.34% top
260 root 0 24M 2476K tunread 2 0:05 0:05 0.00% ppp
PID USERNAME   NICE  SIZE    RES    STATE CPU  TIME   CTIME    CPU COMMAND
82699 ftigeot 0 15M 2872K CPU3 3 0:00 0:00 0.39% top
265 root 0 25M 1172K objcache 1 154:06 154:06 0.00% ppp

Only a reboot allows the machine to resume network operations.

A core dump is available in leaf:~ftigeot/crash/crash.objcache

Actions

Also available in: Atom PDF